Specifications

Part number and specification

 
CABLE DIA. RANGE PART NO. Thread Size ** qs_culus or cruus PART DIMENSIONS CAD
Std. new NFPA 130 * A Max. O.A. Length B Thread Length C Wrenching Nut Flat Size
Minimum Maximum
in. mm. in. mm. in. mm. in. mm. in. mm.
.118 3,0 .157 4,0 4560 4560F NPT 1/8 cruus .91 23,0 .31 8,0 .51 13,0
.157 4,0 .236 6,0 4561 4561F
.138 3,5 .197 5,0 4562 4562F NPT 1/4 cruus 1.14 29,0 .47 12,0 .59 15,0
.197 5,0 .256 6,5 4563 4563F
.256 6,5 .315 8,0 4564 4564F
.138 3,5 .177 4,5 4565 4565F NPT 3/8 cruus 1.26 32,0 .47 12,0 .71 18,0 CAD
.177 4,5 .236 6,0 4566 4566F CAD
.236 6,0 .315 8,0 4567 4567F CAD
.315 8,0 .413 10,5 4568 4568F NPT 3/8 cruus 1.34 34,0 CAD
.236 6,0 .315 8,0 4569 4569F NPT 1/2 qs_culus 1.42 36,0 .59 15,0 .94 24,0
.315 8,0 .433 11,0 4570 4570F
.433 11,0 .590 15,0 4571 4571F NPT 1/2 qs_culus 1.50 38,0
.374 9,5 .492 12,5 4572 4572F NPT 3/4 qs_culus 1.69 43,0 .59 15,0 1.18 30,0 CAD
.492 12,5 .630 16,0 4573 4573F CAD
.630 16,0 .807 20,5 4574 4574F CAD
.551 14,0 .669 17,0 4575 4575F NPT 1 qs_culus 1.89 48,0 .79 20,0 1.42 36,0 CAD
.669 17,0 .827 21,0 4576 4576F CAD
.827 21,0 1.004 25,5 4577 4577F CAD
.787 20,0 .945 24,0 4578 4578F NPT 1-1/4 qs_culus 2.01 51,0 .79 20,0 1.81 46,0 CAD
.945 24,0 1.122 28,5 4579 4579F CAD
1.122 28,5 1.299 33,0 4580 4580F CAD
1.142 29,0 1.299 33,0 4581 4581F NPT 1-1/2 qs_culus 2.20 56,0 .87 22,0 2.17 55,0 CAD
1.299 33,0 1.457 37,0 4582 4582F CAD
1.457 37,0 1.614 41,0 4583 4583F CAD
1.378 35,0 1.575 40,0 4584 4584F NPT 2 qs_culus 2.32 59,0 .87 22,0 2.76 70,0 CAD
1.575 40,0 1.811 46,0 4585 4585F CAD
1.811 46,0 2.047 52,0 4586 4586F CAD
*Gland molded from special TPE (thermoplastic elastomer) **Tapped hole required to maintain ratings. Standard NPT K/O hole can be used only if sealing is not required.
 
 

Features

  • Nickel plated brass construction for superior protection of flexible cables.
  • Nickel-plated finish over brass provides excellent corrosion resistance and durability.
  • IP 68 rated.
  • For use in threaded holes.
  • Multiple sizes for flexible cord diameters ranging from .118″ (3,0 mm) to 2.047″ (52,0 mm).
  • We recommend using the smallest cordgrip that accommodates your cable size.
  • Sealing gland is molded in Thermoplastic Polymer Elastomer (TPE) Material.
  • NFPA parts feature a special TPE Gland tested for heat release and smoke emission (ASTM E 1354) and smoke toxicity (SMP 800).
  • Consult Heyco for availability of NFPA certified Brass Liquid Tight Cordgrips in Pg and Metric hubs.
  • DFARS Compliant

QuickSpecs

Material Nickel-Plated Brass w/TPE Sealing Gland
Certifications culus Certified by UL for Compliance with both Canadian and U.S. requirements under File E51579
NFPA parts: Certified in accordance with American Standard NFPA 130 and European EN 45545-2 (HL 3)
RU logo Recognized under the Component Program of Underwriters’ Laboratories File E51579 to both Canadian and U.S. requirements
Temperature Range -40°F (-40°C) to 212°F (100°C)
IP Rating IP 68, IP 69K
 